Table 2. Removal efficiencies of continuous-flow and batch wastewater reservoirs.

All results are from real scale reservoirs except those quoted as “experimental”.

 

Parameter

Continuous-flow

Batch  30-50 days

Sources

BOD

70 %

90 %

Juanico&Shelef (1991)

Soler et al. (1991)

Juanico&Shelef (1994)

COD

50 %

80 - 90 %

MBAS (detergents)

50 %

90 %

Juanico&Shelef (1991)

Juanico&Shelef (1994)

Nitrogen

 

70 % – 80 %  (1)

Juanico (1999)

Avnimelech (1999)

Bahri et al. (2000)

Phosphorus

 

 

< 30 %

60 % – 85 %  (1)

10 - 30 %

Sala et al. (1994)

Araujo et al. (2000)

(experimental)

Faecal coliforms

90 - 99 %

99.99 % - total

Kott et al. (1978)

Felgner & Sandring (1983)(experimental)

Juanico&Shelef (1991)

Juanico&Shelef (1994)

Liran et al. (1994)

Indelicato et al. (1996)

Athayde et al.

(2000) (experimental)

Streptococcus and Clostridium

 

total

Berná et al. (1986)

Giardia and Cryptosporidium

 

99.99 %

Nasser et al. (2000)

Polivirus I - Chat

 

total

Funderburg et al. (1978) (experimental)

Nematode eggs

 

total

Kouraa et al. (2002)

Barbagallo et al. (2002)

Heavy metals

down to background

concentration in

unpolluted waters (1)

down to background

concentration in

unpolluted waters (1)

Juanico et al. (1995)

Organic micropollutants :

-- phthalates

-- alkyl phenols

-- alkyl benzenes

-- hydrocarbons

60 – 75 %      (2)

 

Muszkat (1999)

 

(1): Data from Juanico and Avnimelech are from two deep reservoirs in series, operated as continuous-flow reactors but with short periods of batch operation. Data by Bahri are from shallow reservoirs.

(2): Soils irrigated with effluents from reservoirs did no present accumulation of studied organic micro pollutants. Those irrigated with effluents from activated sludge plants presented build-up of some organic micro pollutants.

 

 

 

 

Table 3. Summary of the performance of the Ben Slimane plant during the first year of operation.

 

 

 

Raw sewage

Anaerobic

Ponds

Aerated

Lagoons

Facultative

Ponds

Wastewater

Reservoirs

BOD

design value

325

160

80

40

< 20

[ mg/l ]

measured

 

120

70

40

10

F. coliforms

design value

1E7-1E8

1E7

1E6

1E4

< 100

[MPN/100 cc]

measured

 

2E6

6E5

1E4

0-20